Download
Thermostats - Fan Coil/Zone

T6574; T6575; T8574; T8575 Digital Fan-Coil Thermostat

T6570 Series Digital Fan-Coil thermostats provide line voltage on/off control for fans, valves, compressors or auxiliary electric heaters in fan-coil and small air-conditioner applications.

T8570 Series provides low voltage control.
Models are available for control of single stage air-conditioner and various fan-coil units:
- 2-pipe.
- 2-pipe with manual heat/cool changeover.
- 4-pipe with manual heat/cool changeover.
- 4-pipe with automatic heat/cool changeover.
All models are suitable for multiple applications. Changes in output wiring and external links between wiring terminals can configure the thermostat for the appropriate application.
The fan can also be controlled from the thermostat. In some cases it is wired to run continuously and can be switched off with the On/Off switch. Other models can be installed with fan running continuously or cycling with the thermostat.

Compressors and auxiliary electric heaters can be controlled using a relay or contactor controlled by the thermostat.
. Simple user interface.
. Attractive modern styling ideal for offices or hotels.
. Digital display of ambient temperature, with user activated temperature display.
. Digital display shows mode icons when cooling or heating relays operate, or when energy savings mode is active.
. Push button setpoint adjustment.
. Switches allow manual control of system operation and fan speed.
. Energy savings mode - external energy savings input from time switch, occupancy sensors or hotel cardkey
. overrides comfort setpoint with setback heating or cooling setpoint.
. Energy savings input configurable, normally open or normally closed.
. Proportional plus integral (P+I) control algorithm for precision temperature regulation.
. Mounts directly onto wall or standard junction box or vertical junction box with optional adapter plate.
. Installer setup mode allows changes of operating parameters.
. Selectable C or F display.
. Adjustable deadband (some models) for heat and cool control.
. Selectable energy savings set

Dimensions, Approximate: 3 11/16 in. high, 4 3/16 in. wide, 1 7/16 in. deep. (94 mm high, 122 mm wide, 37 mm deep)
Display:
LCD
Humidity Ratings: 5 to 95% RH, non-condensing
Mounting: Direct mounting on horizontal 2 x 4 in. (50mm x 75 mm) single gang electrical box. Mounts on vertical 2 x 4 in. or doubleganged electrical box with optional adapter plate (272878).
Approvals:
Canadian Standards Association:
c/US Certified: File No. 163752


Product Number Application
Type
Color Changeover Supply Voltage
(Vac and Hz)
Switch Position Setting Temperature
Range
System Fan (F) (C)
T6574B1004 2 pipe heat or
cool only
Premier
White®
Automatic optional with
external Aquastat®
controller
120 V 50-60 Hz ON-AUTO HI-MED-LO 50 F to 90 F 10 C to 32 C
T6574B3000 2 pipe heat or
cool only
Premier
White®
Automatic optional with
external Aquastat®
controller
208 V-277 V
50-60 Hz
ON-AUTO HI-MED-LO 50 F to 90 F 10 C to 32 C
T6575B1003 2 or 4 pipe heat/
cool
Premier
White®
Manual 120 V 50-60 Hz HEAT-OFF-COOL HI-MED-LO 50 F to 90 F 10 C to 32 C
T6575B3009 2 or 4 pipe heat/
cool
Premier
White®
Manual 208 V-277 V
50-60 Hz
HEAT-OFF-COOL HI-MED-LO 50 F to 90 F 10 C to 32 C
T6575C1001 4 pipe heat/cool Premier
White®
Automatic, by room
temperature
120 V 50-60 Hz ON-OFF HI-MED-LO 50 F to 90 F 10 C to 32 C
T6575C3004 4 pipe heat/cool Premier
White®
Automatic, by room
temperature
208 V-277 V
50-60 Hz
ON-OFF HI-MED-LO 50 F to 90 F 10 C to 32 C
T6575D1009 4 pipe heat/cool Premier
White®
Automatic, by room
temperature
120 V 50-60 Hz ON-OFF HI-MED-LO
ON-OFF
50 F to 90 F 10 C to 32 C
T6575D3005 4 pipe heat/cool Premier
White®
Automatic, by room
temperature
208 V-277 V
50-60 Hz\
ON-OFF HI-MED-LO
ON-OFF
50 F to 90 F 10 C to 32 C
T8574B1000 2 pipe heat or
cool only
Premier
White®
Automatic optional with
external Aquastat®
controller
24 V 50-60 Hz ON-AUTO HI-MED-LO 50 F to 90 F 10 C to 32 C
T8575B1009 2 or 4 pipe heat/
cool
Premier
White®
Manual 24 V 50-60 Hz HEAT-OFF-COOL HI-MED-LO 50 F to 90 F 10 C to 32 C
T8575C1007 4 pipe heat/cool Premier
White®
Automatic, by room
temperature
24 V 50-60 Hz ON-OFF HI-MED-LO 50 F to 90 F 10 C to 32 C
T8575D1005 4 pipe heat/cool Premier
White®
Automatic, by room
temperature
24 V 50-60 Hz ON-OFF HI-MED-LO
ON-OFF
50 F to 90 F 10 C to 32 C
* TRADELINE models ° SUPER TRADELINE models

<< VOLTAR